Tiger-Vac has an extensive range of Vacuum Cleaner systems specifically designed for the Pharmaceutical Industry. Also suitable for scientific research, semiconductor, and microelectronics applications. Certified to ISO Class 4 Cleanroom and IECEx standard in Australia and New Zealand, ATEX in Europe. OSHA & NFPA in USA, Canada.
![]()
![]()
![]()
![]()
Applications
Dust, Powder, Airborne Microbes, Aerosol Particles, Chemical Vapors, Liquid, Tablets etc.
Industry
Pharmaceutical, Scientific Research, Laboratory, Semiconductor, Microelectronics etc.
Models
EXPLOSION PROOF
Dust Ignition Proof
Dry, Wet & Dry, Fumes
Dry, Wet & Dry, Fumes
CLEANROOM
Dry, Wet & Dry, Vapor
Cleanroom
Cleanroom
CONTAMINATION CONTROL
Up to 5 Stage Filtration,
Cleanroom
Cleanroom
CONTAINMENT
CANISTER
Carcinogenic Powder
Recovery
Recovery
AUTOCLAVABLE
Wet & Dry, Vapor
EMI/RFI Shielded
EMI/RFI Shielded
PNEUMATIC OPERATION
Wet & Dry Cleanroom
IECEx Certified
IECEx Certified
Product Line
Explosion Proof and Dust Ignition Protected
Pharma Vacuum Cleaners
Specifications
Safety Features
- General Cleanup in Hazardous Areas
- Wet & Dry Recovery, Fume Absorption
- Single Phase Electric Operation
- Stainless Steel 304 Construction
- Dry Recovery 22 or 37 Litre
- Liquid Recovery 28 or 47 Litre
- 1000 Wattage
- 1.3 HP Power
- 132 CFM Air Flow
- 4 Wheel Dolly
![]()
![]()
![]()
![]()
- ATEX Ex Certified Explosive Atmospheres.
- CSA Certified HAZLOC Class 1 Div.1 & 2, Class 2 Div. 1 & 2 Groups E, F, G.
- EX-MAT Recovery Guaranteed for Combustible and Conductive Dust.
- Cleanroom ISO 14644-1 Class 4 Compatible.
- ESD Safe, Static Dissipative
- U15 ULPA Filter 99.9995% on 0.18 microns.
- Optional: H14 Hepa Filter 99.995% on 0.3 microns
- EMI/RFI Shielded.
- Activated Carbon Toxic Fume Absorption.
Explosion Proof and Dust Ignition Protected
Pharma Vacuum Cleaners
Specifications
Safety Features
- General Cleanup in Hazardous Areas
- Dry Recovery, Fume Absorption
- Single Phase Electric Operation
- Amtek® By-pass Long Life Motor
- Stainless Steel 316 Construction
- Recovery Tank 19 Litre
- 1200 Wattage
- 1.6 HP Power
- 110 CFM Air Flow
- 4 Wheel Dolly
- Blockage Indicator Light
- CSA Certified HAZLOC Division 2, Class 2 Groups F, G.
- EX-MAT Recovery Guaranteed for Combustible and Conductive Dust.
- ESD Safe, Static Dissipative.
- 5 Stage Filtration System.
- Dual U15 ULPA Filter 99.9995% on 0.18 microns.
- Optional: H14 Hepa Filter 99.995% on 0.3 microns.
- EMI/RFI Shielded.
- Activated Carbon Toxic Fume Absorption.
- Autoclavable up to 121°C.
![]()
![]()
![]()
![]()
Cleanroom Vacuum Cleaner
Pharma Vacuum Cleaners
Specifications
Safety Features
- General Cleanup in Cleanroom Areas
- Wet & Dry Recovery, Fume Absorption
- Single Phase Electric Operation
- Heavy Duty 2 Stage By-pass Motor
- Stainless Steel 304 Construction or Polyethylene Tank with Polished Metal Powerhead
- Dry Recovery Tank 25L, 28L or 47L
- Dry Disposable Bag 6L or 19L
- Wet Recovery 25L, 28L or 47L
- 1200 Wattage
- 1.6 HP Power
- 110 CFM Air Flow
- 4 Wheel Dolly
Model CWR-10
- Liquid Recovery 53L
- Chip Recovery into Sieve Basket 47L
- CSA ANSI/UL 1017, C22.2 No.243 Applicable Requirements.
- ESD Safe, Static Dissipative.
- Less than 10 ohms Resistivity.
- 5 Stage Filtration System.
- Dual U15 ULPA Filter 99.9995% on 0.18 microns.
- Optional: H14 Hepa Filter 99.995% on 0.3 microns.
- EMI/RFI Shielded.
- MRAC Activated Carbon Toxic Fume Absorption.
![]()
![]()
![]()
![]()
Contamination Controlled Environments
Pharma Vacuum Cleaners
Specifications
Safety Features
- General Cleanup in Cleanroom & Hazardous Environments
- Dry Recovery Only
- Single Phase Electric Operation
- Thru-Flow Heavy Duty Motor
- Stainless Steel 316 or Polycarbonate Construction
- Dry Recovery Disposable Filter Bag 7.5L
- Dry Recovery Tank 14L
- 1000 Wattage
- 1.3 HP Power
- 96 CFM Air Flow
- 4 Wheel Dolly
- CSA Applicable requirements: Standards for Electric Vacuum Cleaning Machines, Blower Cleaners.
- Cleanroom ISO 14644-1 Class 4 Compatible.
- 3 Stage Filtration System, ULPA filter, main cloth filter, disposable filter bags.
- Dual U15 ULPA Filter 99.9995% on 0.18 microns.
- Optional: H14 Hepa Filter 99.995% on 0.3 microns.
![]()
![]()
![]()
Containment Canister Contamination Controlled Environment
Pharma Vacuum Cleaners
Specifications
Safety Features
- Designed for Potent Powders in Hazardous Locations
- Safe Containment Canister for collection, containment, and disposal
- Dry Recovery Only
- Single Phase Electric Operation
- Thru-Flow Heavy Duty Motor
- Low-Level Noise 60dBA
- Stainless Steel 316 or Polycarbonate Construction
- Containment Canister Capacity 7.5L
- 1000 Wattage
- 1.3 HP Power
- 96 CFM Air Flow
- 4 Wheel Dolly
- CSA Applicable requirements: Standards for Electric Vacuum Cleaning Machines, Blower Cleaners.
- Cleanroom ISO 14644-1 Class 4 Compatible.
- 5 Stage Filtration System, U15 ULPA filter, H14 HEPA filter, Laminated main cloth filter, Safety filter, Disposable filter bags.
- Dual U15 ULPA Filter 99.9995% on 0.18 microns.
- H14 Hepa Filter 99.995% on 0.3 microns.
- Autoclavable SAE316 Filter Chamber.
- Tool Kit Options: Standard, ESD Safe, Autoclavable.
![]()
![]()
![]()
Autoclavable
Pharma Vacuum Cleaners
Specifications
Safety Features
- General Cleanup in Hazardous Areas
- Designed for Pharmaceutical, Semiconductor, Microelectronic
- Dry Recovery Only or Wet & Dry Recovery
- Single Phase Electric Operation
- Stainless Steel Electropolished Construction to Remove Surface Contamination
- Powerful Suction, Quiet Operation
- Dry Recovery Tank 9.4 Litre
- Disposable Filter Bag 9.8 Litre
- 1000 Wattage
- 1.3 HP Power
- 120 CFM Air Flow
- 4 Wheel Dolly
- ISO 14644-1 Class 4 Cleanroom.
- ESD Safe, Static Dissipative.
- Less than 10 ohms Resistivity.
- Tank and Wheels Autoclavable up to 121°C.
- GMP Standards Compliant.
- Multiple Stage Filtration System
- Dual U15 ULPA Filter 99.9995% on 0.18 microns. Tested IEST-RP-CC001.
- Optional: H14 Hepa Filter 99.995% on 0.3 microns Tested IEST-RP-CC001.
- Aerosol Leak Tested before leaving our factory.
![]()
![]()
![]()
Pneumatic Operation Explosion Proof
Pharma Vacuum Cleaners
Specifications
Safety Features
- For General Cleanup in Hazardous Location
- Single Venturi Pneumatic Operation
- Wet & Dry Recovery
- Stainless Steel SS304 Construction
- Dry Recovery Tank 22 or 37 Litre
- Liquid Recovery Tank 28 or 47 Litre
- Static Dissipative Poly Line & Clips for Easy and Safe Disposal of Recovered Material
- 4 Wheel Dolly with Static Dissipative Wheels
Model ATEX 40A:
- Dry Only or Wet & Dry Recovery
- Low Noise Level 68 dBA
- Stainless Steel 316 Tank is Autoclavable up to 121°C
- IEC and IECEx Certified for Australia
- ATEX Ex Certified Explosive Atmospheres
- CSA Certified HAZLOC Div. 1 Class 1 Groups A, B, C & D. Div 1 Class 2 Groups E, F, G.
- Cleanroom ISO Class 4 Compatible
- EX-MAT Safe Recovery Guaranteed
- ESD Safe, Static Dissipative
- ULPA Filter 99.9995% on 0.18 micron, Tested IEST-RP-CC-001 included.
- Middle Ring Activated Carbon for Toxic Vapors
![]()
![]()
![]()
![]()





























