Tiger-Vac has an extensive range of Vacuum Cleaners for food processing and dust recovery. Designed for general cleaning and the recovery of food, tablets, combustible dust deposits and airborne dust.
Our food processing vacuums are legally certified to national and international standards. Certified to IECEx in Australia, New Zealand and China. ATEX in Europe. OSHA & NFPA in USA, Canada.
![]()
![]()
![]()
Applications
Finely Pulverised Dust, Flour, Grain, Starch, Sugar, Metal Dust, Carbon Black, Coal, Plastic, Tablets etc.
Industry
Food Manufacturing & Processing, Pharmaceutical, Refineries, Heavy Industry etc.
Product Line
Intermittent Duty – Explosion Proof
Combustible Dust, Zone 22
Specifications
Safety Features
For Hazardous Combustible Areas
- Suitable for Finely Pulverised Dust
- Dry Only or Wet & Dry Recovery
- Pneumatic Single or Twin Venturi Operation or
- Electric Single Phase Intermittent Duty Operation
- with 2 Stage By-Pass Motor
- Stainless Steel Tank SAE304
- Detachable Recovery Tank for easy disposal
Optional:
- 2 or 3 Independent Motors
- Brushless Long Life Motor
- Dual Speed, Dual Bypass Ametek Motors
- Disposable Collection Bag
- Recovery Tank 19, 25, 35, 60 or 100 Litre
- Cart with Tool Basket
![]()
![]()
![]()
- IEC IECEx Certified explosion proof for use Australia
Ex h IIC T6 GB, Exh IIC T85ºC Db, IECEx LCIE 17.0076 X - Certified for Division 1 Class I & II, Division 2 Class II Group E, F Conductive Carbonaceous Dust, Carbon Black, Coal, Coke, Dust, etc.
Certified for Group G all Flour Dust, Grain, Starch, Sugar, and other Foods. Wood, Plastic, Chemical Dust, etc.
Certified for Group IIIC Conductive Dust Zone 22 as per International Standards - ESD Safe Prevent Ignition Hazards
- ANSI/UL 1017 & CSA C22.2 Compliant
- Up to 5 x H14 HEPA Filter 99.995% on 0.3 micron
- Manual Filter Shaker
- Aerosol Leak Test prior to dispatch
- Filter Blockage Indicator
- Complete Static Dissipative Tool Kit
CONTINUOUS DUTY – EXPLOSION PROOF
Combustible dust zone 21, 22, gas zone 1, 2
Specifications
Safety Features
For Hazardous Combustible Areas
- Dry Recovery Only including Conductive Metal Dust
- Single Phase or 3 Phase Electric Operation
- 24/7 Continuous Duty TEFC Motor
- Stainless Steel Tank SAE304
- Heavy Duty Powder Coated Cart
- Manual Reverse Purge
- Static Dissipative Reverse Purge Cartridge
- Manual Filter Shaker
Optional:
- Manometer Filter Blockage Indicator
- Noise Reduction Muffler
- True Cyclone Separator System
- Variety of Motor Configurations
- Recovery Tank 35, 55 or 100 Litre
- IEC IECEx Certified explosion proof for use Australia
Ex h IIC T6 GB, Exh IIC T85ºC Db, IECEx LCIE 17.0076 X - Certified for Hazardous Locations as defined in the
National Electrical Code NFPA 70 Div. 1 & 2 Class I & II - ATEX EX Explosion Proof Certified
- EX-MAT Recovery Guaranteed Combustible/Conductive Dusts
- Cleanroom ISO Class 10 Compatible
- ANSI/UL 1017 & CSA C22.2 Compliant
- ESD Safe for Hazardous Locations
- Less than 10 ohms of Resistivity
- H14 Hepa Filter 99.995% on 0.3 micron
- and or U15 Ulpa Filter
- Complete Static Dissipative Tool Kit
- Aerosol Leak Test prior to dispatch
![]()
![]()
![]()
![]()
![]()
![]()
![]()
PNEUMATIC OPERATION
Division 1 Class I, Groups A, B, C, D. Class II, Groups E, F, G, T3C.
Specifications
Safety Features
For Hazardous Combustible Areas
- Dry Recovery Only including Conductive Metal Dust
- Single Phase or 3 Phase Electric Operation
- 24/7 Continuous Duty TEFC Motor
- Stainless Steel Tank SAE304
- Heavy Duty Powder Coated Cart
- Manual Reverse Purge
- Static Dissipative Reverse Purge Cartridge
- Manual Filter Shaker
Optional:
- Manometer Filter Blockage Indicator
- Noise Reduction Muffler
- True Cyclone Separator System
- Variety of Motor Configurations
- Recovery Tank 35, 55 or 100 Litre
- IEC IECEx Certified explosion proof for use Australia
Ex h IIC T6 GB, Exh IIC T85ºC Db, IECEx LCIE 17.0076 X - Certified for Hazardous Locations as defined in the
National Electrical Code NFPA 70 Div. 1 & 2 Class I & II - ATEX EX Explosion Proof Certified
- EX-MAT Recovery Guaranteed Combustible/Conductive Dusts
- Cleanroom ISO Class 10 Compatible
- ANSI/UL 1017 & CSA C22.2 Compliant
- ESD Safe for Hazardous Locations
- Less than 10 ohms of Resistivity
- H14 Hepa Filter 99.995% on 0.3 micron
- and or U15 Ulpa Filter
- Complete Static Dissipative Tool Kit
- Aerosol Leak Test prior to dispatch
![]()
![]()
![]()
![]()
![]()
![]()
![]()
PRE-SEPARATORS – HEC HIGH EFFICIENCY CYCLONES
Use with Low / High Pressure Vacuum or Dust Collector Blowers
Specifications
Safety Features
- For recovery of combustible dust such as flour, rubber, plastics etc.
- Pre-Separator collects up to 95% of dust before entering the vacuum
- HEC high efficiency cyclone. Pre-separation system for fine dust using the cyclone for inertial separation
- SAE304 stainless steel construction for pharma and food industries or H.D. power coated
- Recover capacity: 25L, 85L, 100L, or 200L
- 4-Wheel Cart
- Pre-Separator must be used in conjuntion with a vacuum cleaner that is NRTL certified for use in hazardous locations
- ATEX EX Certified for Explosive Atmospheres
- Certified for Division 1 Class I Group A, B, C, D
Division 1 Class II Group E, F, G
E, F Conductive Carbonaceous Dust, Carbon Black, Coal, Coke, Dust etc.
Certified for Group G all Flour, Grain, Flour, Starch, Sugar and other Food. Wood, Plastic, Chemical Dust etc.
Less than 10 ohms Resistivity
![]()