Tiger-Vac has been manufacturing Cleanroom Vacuums for over 25 years. We have an extensive range of over 40 different models of Cleanroom & Semiconductor Vacuum Cleaner systems. Specifically designed for pharmaceutical, scientific research, semiconductor and microelectronics. Certified to ISO Class 4 Cleanroom previously ISO Class 10 and IECEx explosion proof standard in Australia, New Zealand and China. ATEX certified for Europe and OSHA & NFPA in USA, Canada.
A portable vacuum system is recommended even when a centralised house vac system is in place as the recovered material can be contained rather than spreading through the piping system.
![]()
![]()
![]()
Applications
Dust, Airborne Microbes, Aerosol Particles, Chemical Vapors, Liquid, Broken Glass etc.
Industry
Pharmaceutical, Scientific Research, Laboratory, Semiconductor, Microelectronics etc.
Explosion Proof & Dust Ignition Proof Model
ELECTRIC INTERMITTENT DUTY
ELECTRIC CONTINOUS DUTY
PNEUMATIC OPERATION
ULPA, Autoclavable & Acid Systems Model
ULPA FILTRATION
AUTOCLAVABLE
ACID RECOVERY
Product Line
CLEANROOM VACUUM CLEANER
Electric Operation | Explosion Proof & Dust Ignition Proof
Specifications
Safety Features
- For general cleanup in hazardous locations
- Dry recovery only
- By-pass Ametek long life motor
- Single Phase for intermittent use
- Dry Recovery Only
- Stainless Steel SS316 electropolished construction (except motor housing)
- 19 Liter dry recovery disposable filter bag
- Vacuum blockage indicator light
- 4 Wheel dolly
Optional:
- Containment type with containment canister for the safe collection, containment and disposal of potent compounds included
- CSA Certified for HAZLOC
Class II Division 2 Groups E and F - EX-MAT Safe Recovery Guaranteed for Combustible/Conductive Dust and Flammable Liquid Group F and G
IIIB Cleanroom compatible dust for combustible and toxic / nuisance - ESD Safe, Static Dissipative Powder Coating to prevent ESD
- NFPA 77 compliant for static electricity
- Less than 10 ohms of resistivity
- 5 stage filtration
including ULPA U15 filters for working air and cooling air, double cloth filter, and disposable filter bag - U15 ULPA filtration 99.9995% on 0.18 micron
- Middle Ring Activated Carbon for Absorption of Toxic Fumes and Vapors
- Aerosol leak tested prior to leaving our facility
![]()
![]()
![]()
![]()
CLEANROOM VACUUM CLEANER
Electric Operation | Explosion Proof & Dust Ignition Proof
Specifications
Safety Features
- For General Cleanup in Hazardous Location
- Single Phase explosion proof dust ignition proof motor
- Intermittent Use
- Wet & Dry recovery
- Stainless Steel SS304 construction
- Static dissipative poly liner and clip for easy and safe disposal of recovered material
- 19 Liter dry recovery disposable filter bag
- 4 Wheel dolly mounted with static dissipative wheels
- Complete autoclavable tool kit
![]()
![]()
![]()
![]()
![]()
- Cleanroom ISO Class 4 Compatible (former class 10)
- CSA Certified for HAZLOC Class I Division Class 1 & 2 Groups D, T3C
Class II Division 1 & 2 Groups E, F, and G - EX-MAT Safe Recovery Guaranteed for Combustible/Conductive Dust and Flammable Liquid
- ESD Safe, Static Dissipative Powder Coating to prevent ESD
- Less than 10 ohms of resistivity
- ULPA U15 Filter with efficiency of 99.999% at 0.12 micron. Efficiency 99.9995% on 0.18 micron
- Middle Ring Activated Carbon for Absorption of Toxic Fumes and Vapors
- Aerosol leak tested prior to leaving our facility
CLEANROOM VACUUM CLEANER
Pneumatic Operation | Explosion Proof & Dust Ignition Proof
Specifications
Safety Features
- For General Cleanup in Hazardous Location
- Single Venturi Pneumatic Operation
- Wet & Dry Recovery
- Stainless Steel SS304 Construction
- Dry Recovery Tank 22 or 37 Litre
- Liquid Recovery Tank 28 or 47 Litre
- Static Dissipative Poly Line & Clips for Easy and Safe Disposal of Recovered Material
- 4 Wheel Dolly with Static Dissipative Wheels
![]()
![]()
![]()
![]()
![]()
![]()
![]()
- Cleanroom ISO Class 4 compatible (former class 10)
- Designed for hazardous location as defined in NFPA70
Division 1 Class I groups A, B, C, and D
Division 1 Class II groups E, F, and G - IEC and IECEx Certified for Australia, IECEx LCIE 17.0076 X
- ATEX Ex certified explosive atmospheres
- EX-MAT safe recovery guaranteed
- ESD safe, static dissipative
- ULPA Filter with an efficiency of 99.999% on 0.12 micron, 99.9995% on 0.18 micron. Tested IEST_RP_CC001
- MRAC middle ring with activated carbon for toxic fumes and vapors
PROCESS MACHINE ATTACHABLE
Electric Operation – Continuous Duty | Cleanroom Vacuum Cleaner
Specifications
Safety Features
- For general areas in the food and pharma processing including tablet recovery
- Dry recovery only
- Single Phase or 3 Phase electric operation continuous duty motor mounted vertically
- Designed to be attached to process machines or 4 wheel dolly mounted for mobile unit
- Low Noise 64 dBA
- Stainless steel or white powder coated construction
- Recovery capacity 15 liter tank
- Recovery disposable filter bag 7.5 liter
- ISO Cleanroom Class 4 Compatible (formerly class 10)
- U15 ULPA Filter with an efficiency of 99.999% on 0.12 micron, 99.9995% on 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822
- H14 HEPA Filter with an efficiency of 99.995% on 0.3 micron. Tested IEST-RP-CC001. H14 by MPPS method as per EN 1822 and OSHA compliant
- Aerosol leak tested before leaving our facility
![]()
![]()
![]()
![]()
PROCESS MACHINE ATTACHABLE
Electric Operation – HAZLOC | Cleanroom Vacuum Cleaner
Specifications
Safety Features
- Process machine attachable
- Designed for general cleanup, tablet recovery
- Dry only recovery
- Continuous duty single phase electric operation
- TEFC explosion proof motor legally certified
- Noise reduction muffler
- Stainless steel 304 construction
- Vertical mounting for areas with space constraints
- Optional CFB conductive filter bag or MRPFT manual reverse purge with filter tubes system
- Static dissipative poly liner and retainer clip for the easy and safe disposal of recovered materials
- Includes complete static dissipative tool kit
- Optional: other motor performances available
- Cleanroom ISO Class 4 Compatible (former class 10)
- IEC IECEx certified for Australia
Equipment protection level of EPL Db and EPL Gb, IECEx LCI 10.0040 X - CSA Certified for HAZLOC
Division 1 class I group D and class II groups F, G and T3C
Division 1 class II group E (metal dust) motor and switch available
Division 2 class 1 group D and class II groups f, g, and T3C - EX-MAT safe recovery guaranteed for combustible/conductive dust and flammable liquid
- ESD Safe, static dissipative powder coating to prevent ESD
- Less than 10 ohms of resistivity
- ULPA U15 Filter with an efficiency of 99.999% at 0.12 micron and an efficiency 99.9995% on 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822
- Aerosol leak tested prior to leaving our facility
- Motor and switch for use in presence of conductive metal dust is available. North America: class II group E, Europe: dust group IIIC
![]()
![]()
![]()
![]()
![]()
![]()
![]()
PROCESS MACHINE ATTACHABLE
Cleanroom Vacuum Cleaner
Specifications
Safety Features
- Designed to be attached to process machines and for general cleanup in the Food industry or tablet recovery in the Pharmaceutical industry
- Dry recovery only
- Continuous duty single phase or 3 phase motor vertically mounted
- Stainless steel SS304 construction
- Dry recovery tank 35 litre
- ARP automatic reverse purge with static dissipative reverse purge cartridge
- Available in stainless steel or white powder coated, or combination construction
- Fixed unit or 4 wheel portable unit
- Cleanroom ISO Class 4 Compatible (former class 10)
- All electrical components certified by and NRTL such UL, CSA or ETL
- ESD Safe, Static Dissipative
- U15 ULPA Filter with an efficiency of 99.999% on 0.12 micron and 99.9995% on 0.18 micron. U15 by MPPS method as per EN 1822. Tested IEST-RP-CC001
- H14 HEPA Filter 99.995% on 0.3 micron. H14 by MPPS method as per EN 1822. Tested IEST-RP-CC001
- Aerosol leak tested before leaving our facility
![]()
![]()
![]()
![]()
MANUAL REVERSE PURGE SYSTEM
Cleanroom Vacuum Cleaner
Specifications
Safety Features
- For hazardous & combustible areas, legally certified
- Dry recovery only
- Continuous duty 3 phase TEFC motor, third party certified
- Stainless steel SS304 construction except for cart
- Detachable recovery tank 50 liter
- MRP manual reverse purge with static dissipative reverse purge cartridge
- Optional ARP automatic reverse purge filter cleaning system
- Static conductive aluminized spun bond reverse purge cartridge is contained within a removable filter
- Static dissipative poly liner and clip for easy and safe disposal of recovered material
- Static dissipative wheels
- Vertical mounting for areas with space constraints
- Equipped with CSMT, cartridge with suspended motor top
- Other motor performances available
![]()
![]()
![]()
![]()
![]()
![]()
![]()
- Cleanroom ISO Class 4 Compatible (former class 10)
- IEC IECEx certified for Australia
Equipment protection level of EPL Db and EPL Gb, IECEx LCI 10.0040 X - CSA Certified for HAZLOC
Division 1 class I group D and class II groups F, G and T3C
Division 1 class II group E (metal dust) motor and switch available
Division 2 class 1 group D and class II groups f, g, and T3C - EX-MAT safe recovery guaranteed for combustible/conductive dust and flammable liquid
- ESD Safe, static dissipative powder coating to prevent ESD
- Less than 10 ohms of resistivity
- ULPA U15 Filter with an efficiency of 99.999% at 0.12 micron and an efficiency 99.9995% on 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822
- H14 HEPA filter optional
- Aerosol leak tested prior to leaving our facility
- Motor and switch for use in presence of conductive metal dust is available. North America: class II group E, Europe: dust group IIIC
ULPA CLEANROOM VACUUM CLEANER
Backpack, Handheld, Golfcart
Specifications
Safety Features
- For general cleanroom areas include biohazard applications
- Dry recovery only
- Single phase electric operation
- Stainless Steel 304 construction
- Recovery capacity 0.4 – 1.2 Litre
- Available as Backpack, Handheld, and Golfcart versions
- Includes complete tool kit
![]()
![]()
![]()
![]()
- ISO Cleanroom Class 4 ISO 14644-1 (former class 10)
- Static Free & ESD Safe
- EMI/RFI Shielded
- Less than 10 ohms of resistivity
- Multi stage Filtration System
- Containment H14 HEPA filter with an efficiency of 99.995% on 0.3 micron
- Containment U15 ULPA Filter with an efficiency of 99.999% on 0.12 micron and 99.9995% on 0.18 micron
ULPA CLEANROOM VACUUM CLEANER
Contamination Controlled Environment
Specifications
Safety Features
- For contamination controlled areas
- Dry recovery only
- Single phase electric operation
- Thru-Flow heavy duty motor
- Low noise level 60dBA at 2m
- Plastic or stainless steel recovery tank
- Recovery capacity 15 litre tank
- Recovery disposable filter bag 7.5 Litre
- 4 wheel dolly mounted for easy maneuverability
- Includes complete tool kit
![]()
![]()
![]()
- ISO Cleanroom Class 4 Compatible (former class 10)
- Meets CUS ETL standards for electric vacuum cleaning machines and blower cleaners UL-1017
- 3 Stage Filtration System includes U15 ULPA Filter 99.9995% on 0.18 micron, main cloth filter, disposable filter bags
CONTAINMENT CANISTER
Potent Carcinogenic Powders | Cleanroom Vacuum Cleaner
Specifications
Safety Features
- Designed for recovery of potent carcinogenic powders
- Equipped with a safe containment canister for collection, containment and disposal
- Dry only recovery
- Single phase electric operation
- Powerful dual speed thru-flow motor
- TELECOM package available
- 4 wheel dolly mounted for easy maneuverability
- 3 optional tool kits: standard, ESD safe and autoclavable
![]()
![]()
![]()
![]()
Safety Features
- ISO Cleanroom Class 4 compatible (former class 10)
- EMI/RFI shielded
- Autoclavable SAE 316 filter chamber and wheel base
- Static dissipating & ESD
safe - Less than 10 ohms resistivity
- 5-stage filtration system incuding ULPA, HEPA, PTFE laminated main cloth filter, safety filter, and disposable filter bag
- U15 ULPA filter with efficiency of 99.999% on 0.12 micron and 99.9995% on 0.18 micron
- H14 HEPA filter with an efficiency of 99.99% on 0.3 micron
EMI/RFI SHIELDED – ACTIVATED CARBON
Electric Operation | Cleanroom Vacuum Cleaner
- Designed for contamination controlled environments
- Wet & Dry recovery
- Single phase electric operation
- Heavy duty 2-stage bypass motor
- 1.6 HP powerful suction
- Stainless steel recovery tank
- 4 wheel dolly mounted for easy maneuverability
- Includes complete tool kit
![]()
![]()
![]()
![]()
- ISO Cleanroom Class 4 Compatible (former class 10)
- CSA ANSI/UL 1017 CSA C22.2 No.243 compliant
- EMI / RFI shielded
- Static dissipating & ESD safe
- Less than 10 ohms resistivity
- 5-stage filtration system
2 x U15 ULPA Filters with an efficiency of 99.999% on 0.12 micron and 99.9995% on 0.18 micron
Double cloth filter
Disposable filter bag - MRAC middle ring with activated carbon for absorption toxic/noxious fumes and vapors
AUTOCLAVABLE
New Generation Electric Operation | Cleanroom Vacuum Cleaner
Specifications
Safety Features
- For General Areas & Combustible Areas
- Designed specifically for the Pharmaceutical, Semiconductor, and Microelectronics industries
- Dry recovery only
- Single phase electric operation
- Powerful suction, quiet operation
- Complete electropolish stainless steel construction to remove surface contamination
- Disposable collection bag
- Variety of accessories available including autoclavable and ESD safe
![]()
![]()
![]()
![]()
![]()
- ISO Cleanroom Class 4 ISO 14644-1 conditions compatible (class 10 as per FED STD 209E)
- Less than 10 ohms Resistivity
- Static dissipating and ESD safe
- Multi-stage filtration system
Upstream H14 HEPA filter and downstream U15 ULPA filter
Primary filter is a disposable collection bag and polyester filter with filtration Class M as per IEC 60335-2-69 - H14 HEPA filter with an efficiency of 99.995% on 0.3 micron. Tested IEST-RP-CC001
- U15 ULPA filter with an efficiency of 99.999% on 0.12 micron and 99.9995% on 0.18 micron. Tested IEST-RP-CC001
- Recovery tank is made of SS316 stainless steel and is fully autoclavable up to 121ºC including white nylon wheels. Alternative static conductive grey wheels, non autoclavable
AUTOCLAVABLE
New Generation Electric Operation | Cleanroom Vacuum Cleaner
Specifications
Safety Features
- For general areas & combustible areas, legally certified explosion/dust ignition proof by OSHA approved nationally recognized testing laboratory (NRTL)
- Dry only or Wet & Dry recovery
- Single venturi operation
- Powerful suction, quiet operation 68dBA
- Stainless steel 304/316 Construction
- Disposable collection bag & primary filter
- Included complete static dissipative tool kit
- Pressure regulator included. Regulator is adjustable between 0 psi. (0 bar) to 150 psi. (10 bars). It is factory set at 80 psi. (5.5 bars) for ideal performance and noise level
![]()
![]()
![]()
![]()
![]()
![]()
- Cleanroom ISO Class 4 compatible (former class 10)
- Designed for hazardous location as defined in NFPA70
Division 1 Class I groups A, B, C, and D
Division 1 Class II groups E, F, and G - ATEX Ex certified explosive atmospheres
- EX-MAT safe recovery guaranteed
- Less than 10 ohms of resistivity
- ESD safe, static dissipative
- ULPA U15 filter downstream, with an efficiency of 99.999% on 0.12 micron, 99.9995% on 0.18 micron. Tested IEST_RP_CC001
- HEPA H14 filter upstream for dry version
- MRAC middle ring with activated carbon for toxic fumes and vapors
- Recovery tank SAE316 stainless steel and white nylon wheels are fully autoclavable up to 122°C
- Static conductive grey wheels (non-autoclavable) are available upon request
AUTOCLAVABLE
Dry Only or Wet & Dry – New Generation Electric Operation | Cleanroom Vacuum Cleaner
Specifications
Safety Features
- Designed specifically for the Pharmaceutical, Semiconductor, and Microelectronic industries
- Dry recovery only or Wet & Dry recovery
- Single phase electric operation
- 2-stage bypass motor provides powerful suction and quiet operation
- All stainless steel construction with anti-contamination electropolish finish
- Easy storage of power cord on the powerhead
- Variety of accessories are available including autoclavable and ESD safe
![]()
![]()
![]()
![]()
![]()
- ISO Class 4 Cleanroom conditions compatible as defined in ISO 14644-1 (Class 10 as per FED STD 209E)
- Static Dissipating & ESD safe
- Less than 10 ohms resistivity
- Compliant with GMP standards
- Multi-stage filtration system
2 x absolute U15 ULPA filters with efficiency 99.999% on 0.12 micron and 99.9995% on 0.18 micron. Rated U15 as per EN 1822 as placed at both the working air and the cooling air exhausts of the vacuum system to ensure cleanroom compatibility - Polyester primary filters & disposable collection bag filtration Class M IEC 60335-2-69
- Autoclavable parts up to 121°C: stainless steel recovery tank, floater liquid cut-off, tools, and white nylon wheels
AUTOCLAVABLE ACID RECOVERY
Vacuum Cleaner Attachment
Specifications
Safety Features
- Designed for the recovery of liquid acids and corrosive liquids in conjunction with a cleanroom vacuum cleaner
- Dry Recovery Optional
- Stainless Steel SS304 Construction with Electropolish Finish
- 4 wheel dolly mounted for easy maneuverability
- Includes complete tool kit
- Cleanroom ISO Class 4 compatible (former class 10). Suitable for pharmaceutical industry
- ATEX Ex Explosive Atmosphere Certified
- KINA 3 activated carbon for absorption of chloride and acid fumes and vapors.
- Less than 10 ohms of resistivity
- ESD Safe and Static Dissipative
![]()
![]()
![]()
ACID RECOVERY – EMI/RFI SHIELDED
Activated Carbon | Cleanroom Vacuum Cleaner
Specifications
Safety Features
- Designed for the recovery of acids & corrosive liquids
- Heavy duty 2-stage by pass motor
- Acid resistant polyethylene, nylon
and PVC construction - Includes complete tool kit
- Cleanroom ISO Class 4 compatible (former class 10)
- U15 ULPA filter with efficiency of 99.999% on 0.12 micron and 99.9995% on 0.18 micron. Tested IEST-RP-CC001. U15 by MPPS method as per EN 1822
- EMI/RFI Shielded
- KINA 3® activated carbon for absorption of chloride and acid vapors (HF, HCL etc.)
- Aerosol leak tested prior to leaving our facility
![]()
![]()
![]()


































